Which furnace?

Discussion in 'Other Equipment' started by Robert Squire, Dec 14, 2017.

  1. DMC

    DMC Scott Hudson

    Call me please.
    804 five one 3 7153
     
  2. DMC

    DMC Scott Hudson

    Broken element or bad connection at top of element. See the "open circuit" light?
     
  3. basler

    basler New Member

    Thank you Scott I ll give you call tomorrow morning
     
  4. Erykd1

    Erykd1 Member

    If your amps are showing zero, there is an incomplete circuit with your heating elements. Whenever I have this happen, this is my checklist. First thing, check to make sure no heating elements are broken, open top cover and use a multimeter to check for continuity. If all is good, check to make sure all heating element clamps are tightened well. If it still doesn't heat, take off each clamp one by one and check for any corrosion along the tops and clean with wire brush and retighten. Hope this helps!


    Sent from my iPhone using Tapatalk
     
  5. Robert Squire

    Robert Squire Active Member

    Our Shenpaz Pro plus sintering furnace's screen is only showing white, no dialog. It powers on. Anyone have any idea as to what the issue may be?
     

    Attached Files:

  6. DMC

    DMC Scott Hudson

    Some DC power supply issue? 5v 12v

    Fuse or power supply
     